It remains mechanically unchanged and for good reason. The system is programmed to regenerate at 12 am or 2 am. The various regeneration positions may be dialed manually by turning the knob on the front of. Fleck 5600 econominder softener installation guide 25july if you have a water softener and decide to set the brine tank next, run your fleck 5600 valve through a manual regeneration cycle by simply turning fleck 5600 econominder softener installation guide 25july created date. Once all regeneration steps are complete the valve returns to service and resumes normal operation. Install the water softener with the inlet, outlet and drain connections made according to manufacturers.

Jul 20, 2017 when the softener regenerates it will need to send water to drain. Some models simply have a handcontrolled knob that you can turn to regenerate. Unit will regenerate tonight when the gallon capacity reaches zero. I want to reset the time for regeneration to 7 pm not the 3 am. Help whow to do a manual regeneration of a model 5600 econominder softner i let the salt run out of the brine tank and would like to do a manual regeneration rather than wait for the softner to get to x number of gallons of useage. Fleck 5600 econominder 48000 grain mechanical meter water. Water softeners and backwashing filters that utilize the proven reliability of the fleck valve.

For forced regeneration you have to choose the regen option. Ever wonder what the different dials or gears on your water softener are for. Your new system comes with a printed fleck service manual, which along with this startup guide will help guide you in the. For electronic valves, please refer to the manual regeneration part of the timer operation section. The iron filter will remove up to 68 ppm of ferrous iron from the water, which is very userfriendly. With proper installation and a little routine maintenance your system will be providing filtered water for many years. If you have the 5600 econominder on demand metered control valve then you have one of the best all time selling control valves and they last for decades and decades providing reliable service. Is the fleck 5600 water softener a good fit for your needs. How to manually regenerate a fleck 5600 softener h2o. Although we have generally been satisfied with our 14year old fleck 5600 econominder, the first cupful or so of water from the faucet has recently been tasting salty after each regeneration. Manually index the softener control into the in service position and let water flow into the resin tank.

Fleck 5600 from the rear showing the inlet and outlet end. When not in a cleaning cycle, the system is in a service position. Manually index the softener control into the service position and let water flow into the resin tank. Fleck 5600 econominder service manual pdf download manualslib. Fleck 5600 econominder capacity wheel not rotating terry. To set the time of day, push the red button and spin the 24hour gear until the present time of day is visible above the time of day arrow. Start regeneration cycle manually if water is hard. Use this water softener capacity calculator or our cylinder calculators to find the capacity of your softener complete 5600 operating manual.

How to set regeneration time on a 5600 econominder terry. During the brine draw bd stage of the regeneration of the fleck 5600sxt this drain line flow is passed over the injector an inside component in the control valve to create suction to draw the brine solution out of the brine tank. Non digital fleck 5600 econominder not using much if any. Use this water softener capacity calculator or our cylinder calculators to find the capacity of your softener. When the water flow stops, open a softened water tap until all air is released from the lines. A fleck 5600 metered softener keeps track of the gallons that it treats and when it reaches a preset number programmed by the technician, it will automatically put itself through a regeneration cycle at 2 am. This fleck 5600 piston and interior parts rebuild kit contains the most commonly replaced internal parts on the fleck 5600 water softener typically as these parts age and wear, it is recommended that they be replaced together as a kit. To manually regenerate the valve, turn the manual regeneration knob clockwise until it reads regen. Rotate program wheel counterclockwise until it stops at regeneration position. This item fleck 5600 econominder 48000 grain mechanical meter water softener fleck 5600sxt metered ondemand 48,000 grain water softener with brine tank, bypass and 1 adapters fleck 5600 softener valve rebuild kit includes piston 6010200 seals spacers 60125 brine valve 60032. Up guide thank you for purchasing a clean water system. This is an instructional video that explains how to adjust the settings for the. Other considerations depending on the size of your water softener, a regeneration cycle typically takes about 30 to 60 minutes and uses anywhere from 40 to 60 gallons of water.

Because our company installs the fleck brand water softener, we have provided you with instructions below for two of the most common models we sell. Help whow to do a manual regeneration of a model 5600. Each time the program switch position changes, the valve will advance to the next regeneration step. Fleck 5600 timered water softener discount water softeners.

What repair is required and what would the approximate cost be. Fill in pertinent information on page 3 for future reference. If an immediate regeneration valve has been specified the above still applies. The fleck 5600 has been typically used for rental systems due to its reliability. Fleck 5600 econominder service manual pdf download. The valve will get stuck trying to complete a regeneration cycle. Oct 30, 2020 just bought a fleck 64,000 grain 5600sxt.

If the valve came with a separate electronic timer service manual, refer to the timer operation. How to manually regenerate the fleck 5600 valve youtube. To regenerate the fleck 5600 valve used on softener, without working timer motor. These directions work for all nondigital models of the fleck brand water softener. Pressing the extra cycle button during a regeneration cycle immediately advances the valve to the next cycle step position and resumes normal step timing. Learn how to manually regenerate also called backwash your fleck 5600 softener with this simple explanation and video tutorial.

Fleck 5600 control valve parts water softener parts. Very slowly turn the inlet knob on the bypass valve towards the service. To manually regenerate the valve, turn the manual regeneration knob clockwise. Fleck 5600 metered softener cycle steps and times h2o. How to manually regenerate a fleck 5600 softener h2o equipment. Another problem that can occur with the fleck 5600 econominder metered valve. Turn the knob located in the middle of the valve clockwise. The way to tell if this part needs replacement is to remove the meter dome, turn the cable attached by.

Brine refill until it refills back to normal water level in brine tank 6 16 minutes. Since the fleck 5600 comes in a few different styles mechanical, digital, etc. Dec 07, 2018 learn how to manually regenerate also called backwash your fleck 5600 softener with this simple explanation and video tutorial. Scope of the documentation the documentation provides the necessary informatio n for appropriate use of the product.

Fleck systems model 5600 mechanicalmetered water softener control valve. Piston stuck 5600 control valve it is very common for the main and brine pistons of the fleck 5600 to need replacement after 5 10 years of use. From there, you can set the regeneration time, water hardness, and more. When fleck 5600sxt softener brine tank is full of water. When this part goes bad, your brine tank can fill full of water in service and overflow or regeneration may not take place at all. The way to tell if this part needs replacement is to remove the meter dome, turn the cable attached by hand and observe the small white gears inside. Fleck 5600 econominder installation guide before you assemble your new system, be sure that the following first plug in your 5600 econdominder valve to a nearby outlet. The fleck 5600 water softener is one of the best whole house water softeners. Fleck has led the way for more than 50 years in advancing control valve technology.

Fleck 2510 service manual pdf fleck 5600 brochure pdf fleck 5600 owners manual pdf model 5600 service manual. To learn the exact process by which you can initiate a manual regeneration on your water softener, consult your water softeners owners manual. Valves featured include the 5600, 2510, 9100, 2900 and many more. How to reset the time on your water softener peterson salt. This video shows you how to set the system through an immediate regeneration.

How to adjust the time of day on your 5600 econominder or 5600 time clock fleck water softener nondigital. Fleck 5600 econominder water softening system 9 x 48. For the fleck 5600sxt, you enter the programming interface by pressing and holding the up and down arrows for about 4 to 5 seconds until the screen changes. To manual ly regenerate the valve, turn the manual regeneration knob clockwise until it reads regen. The water softener should be installed with the inlet, outlet and drain. Fleck 5600 metered water softener on demand control head.

Brine rinse 50 minutes and no less, as this is the most critical cycle rapid rinse 10 minutes. Model 5600 econominder 1manually index the softener control to the in service position and let water flow into the resin tank. Install the water softener with the inlet, outlet, and drain connections made according to manufacturers. View and download fleck 5600 service manual online. The process by which you can force a manual regeneration of your water softener depends entirely on the make and model of the softener. Now, your softener will instantly begin read the full article. Fleck 5600 control valve parts, electronic turbine meter assembly. Very often this occurs at the beginning of the brine rinse cycle. Fleck 5600 and 5600sxt this is only a general instruction reference, be sure to read your owners manual for any special instructions on your particular softener. The iron filter will remove up to 68 ppm of ferrous iron from the water, which is. Its an iron filter thats included with this fleck 5600 water softener.

A fleck 5600 water softener goes through a regeneration cycle every 315 days in ct. This fleck 5600 econominder water softener has a great unique feature. With over 30 years of sales and service experience as former president of water treatment company, inc. High capacity imported resin 8% crosslink, bypass with 34.

Once you hear the clicks, you should see the words regen in the cutout. Fleck 5600 econominder water softening system 10 x 54. Manual regeneration process of water softener hunker. Set the time of day, by pushing the regeneration button in. Manually dial the various regeneration positions by turning the knob on the front of the control until the indicator shows that the softener is in the desired. Ws1cs downflow regeneration metered control valves. Install the water softener with the inlet, outlet and drain connections made according to manufacturers recommendations and to meet applicable plumbing codes page 2 white dot grains per gallons water hardness scale gallons label. Find fleck 5600 valves and fleck 5600 water softeners. The cycles times for the fleck 5600 control head are as follows. The manual regeneration feature facilitate the user to set a timer for meter regeneration process. Install the water softener with the inlet, outlet and drain connections made according to manufacturers recommendations and to meet applicable plumbing codes. Our fleck 5600 timered water softener is one of the simplest and most reliable water softeners on the market today and it has been for over 25 years. We have a 5600 econominder salt water softener and it normally regenerates about 34 am or so. Start a manual backwash by turning the manual regeneration knob clockwise to backwash.